{"id":661,"date":"2025-06-26T08:06:25","date_gmt":"2025-06-26T08:06:25","guid":{"rendered":"https:\/\/hocera.com\/?post_type=product&#038;p=661"},"modified":"2025-12-31T08:27:22","modified_gmt":"2025-12-31T08:27:22","slug":"hocera-ht-high-strength-zirconia-block","status":"publish","type":"product","link":"https:\/\/hocera.com\/en\/product\/hocera-ht-high-strength-zirconia-block\/","title":{"rendered":"Hocera HT High Strength Zirconia Block | 1350 MPa 3Y-TZP"},"content":{"rendered":"<h2 data-start=\"549\" data-end=\"592\">Hocera HT High-Strength Zirconia Block<\/h2>\n<p data-start=\"593\" data-end=\"667\"><strong data-start=\"593\" data-end=\"667\">1350 MPa 3Y-TZP Zirconia for Long-Span &amp; Masking-Critical Restorations<\/strong><\/p>\n<hr data-start=\"669\" data-end=\"672\" \/>\n<h3 data-start=\"674\" data-end=\"717\">Product Background &amp; Material Rationale<\/h3>\n<p data-start=\"719\" data-end=\"911\">The <strong data-start=\"723\" data-end=\"765\">Hocera HT High-Strength Zirconia Block<\/strong> is developed specifically for <strong data-start=\"796\" data-end=\"855\">high-load restorations and complex substrate conditions<\/strong> where conventional zirconia materials show limitations.<\/p>\n<p data-start=\"913\" data-end=\"1297\">In daily laboratory practice, technicians often face three recurring challenges:<br data-start=\"993\" data-end=\"996\" \/><strong data-start=\"996\" data-end=\"1043\">insufficient strength for long-span bridges<\/strong>, <strong data-start=\"1045\" data-end=\"1081\">poor masking over dark abutments<\/strong>, and <strong data-start=\"1087\" data-end=\"1130\">dimensional instability after sintering<\/strong>.<br data-start=\"1131\" data-end=\"1134\" \/><strong data-start=\"1134\" data-end=\"1179\">Hocera HT directly addresses these issues<\/strong> through a strength-focused 3Y-TZP formulation combined with controlled translucency and optimized sintering behavior.<\/p>\n<hr data-start=\"1299\" data-end=\"1302\" \/>\n<h3 data-start=\"1304\" data-end=\"1353\">Mechanical Strength Based on Proven Standards<\/h3>\n<p data-start=\"1355\" data-end=\"1515\">Hocera HT zirconia achieves a <strong data-start=\"1385\" data-end=\"1418\">flexural strength of 1350 MPa<\/strong>, based on a dense <strong data-start=\"1437\" data-end=\"1499\">3Y-TZP (yttria-stabilized tetragonal zirconia polycrystal)<\/strong> microstructure.<\/p>\n<p data-start=\"1517\" data-end=\"1784\">Because of this material composition, the zirconia core maintains <strong data-start=\"1583\" data-end=\"1632\">high fracture resistance under cyclic loading<\/strong>, even in posterior regions.<br data-start=\"1660\" data-end=\"1663\" \/>As a result, laboratories can confidently fabricate <strong data-start=\"1715\" data-end=\"1746\">6\u201314 unit long-span bridges<\/strong> without over-dimensioning connectors.<\/p>\n<ul data-start=\"1786\" data-end=\"1949\">\n<li data-start=\"1786\" data-end=\"1825\">\n<p data-start=\"1788\" data-end=\"1825\">Tested according to <strong data-start=\"1808\" data-end=\"1825\">ISO 6872:2015<\/strong><\/p>\n<\/li>\n<li data-start=\"1826\" data-end=\"1893\">\n<p data-start=\"1828\" data-end=\"1893\">Fatigue resistance verified at <strong data-start=\"1859\" data-end=\"1893\">1.5 million cycles (ISO 14801)<\/strong><\/p>\n<\/li>\n<li data-start=\"1894\" data-end=\"1949\">\n<p data-start=\"1896\" data-end=\"1949\">Connector stability confirmed at <strong data-start=\"1929\" data-end=\"1949\">0.3 mm thickness<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1951\" data-end=\"2083\">This performance level allows technicians to meet strength requirements <strong data-start=\"2023\" data-end=\"2082\">without sacrificing anatomical design or occlusal space<\/strong>.<\/p>\n<hr data-start=\"2085\" data-end=\"2088\" \/>\n<h3 data-start=\"2090\" data-end=\"2139\">Masking Performance for Discolored Substrates<\/h3>\n<p data-start=\"2141\" data-end=\"2346\">In clinical reality, many restorations involve <strong data-start=\"2188\" data-end=\"2247\">C3\u2013C4 discolored dentin, metal posts, or titanium bases<\/strong>.<br data-start=\"2248\" data-end=\"2251\" \/>Therefore, zirconia must provide sufficient masking <strong data-start=\"2303\" data-end=\"2345\">before any staining or layering begins<\/strong>.<\/p>\n<p data-start=\"2348\" data-end=\"2607\">Hocera HT offers <strong data-start=\"2365\" data-end=\"2396\">38% controlled translucency<\/strong>, which balances light transmission and opacity.<br data-start=\"2444\" data-end=\"2447\" \/>Compared with standard HT zirconia materials, this formulation improves masking efficiency by <strong data-start=\"2541\" data-end=\"2562\">approximately 22%<\/strong>, while still maintaining natural brightness.<\/p>\n<p data-start=\"2609\" data-end=\"2648\">Consequently, laboratories can achieve:<\/p>\n<ul data-start=\"2649\" data-end=\"2769\">\n<li data-start=\"2649\" data-end=\"2674\">\n<p data-start=\"2651\" data-end=\"2674\">Stable shade outcomes<\/p>\n<\/li>\n<li data-start=\"2675\" data-end=\"2711\">\n<p data-start=\"2677\" data-end=\"2711\">Reduced reliance on heavy stains<\/p>\n<\/li>\n<li data-start=\"2712\" data-end=\"2769\">\n<p data-start=\"2714\" data-end=\"2769\">More predictable anterior\u2013posterior color consistency<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"2771\" data-end=\"2774\" \/>\n<h3 data-start=\"2776\" data-end=\"2829\">Hybrid Abutment &amp; Metal Replacement Compatibility<\/h3>\n<p data-start=\"2831\" data-end=\"2946\">Hocera HT is designed for <strong data-start=\"2857\" data-end=\"2893\">direct bonding to titanium bases<\/strong>, enabling reliable <strong data-start=\"2913\" data-end=\"2945\">hybrid abutment restorations<\/strong>.<\/p>\n<p data-start=\"2948\" data-end=\"3158\">Thanks to its material density and stable coefficient of thermal expansion, the zirconia performs consistently in <strong data-start=\"3062\" data-end=\"3097\">metal-ceramic replacement cases<\/strong>, eliminating corrosion risks and improving biocompatibility.<\/p>\n<ul data-start=\"3160\" data-end=\"3282\">\n<li data-start=\"3160\" data-end=\"3191\">\n<p data-start=\"3162\" data-end=\"3191\">Certified under <strong data-start=\"3178\" data-end=\"3191\">ISO 13356<\/strong><\/p>\n<\/li>\n<li data-start=\"3192\" data-end=\"3232\">\n<p data-start=\"3194\" data-end=\"3232\">FDA-cleared for dental restorative use<\/p>\n<\/li>\n<li data-start=\"3233\" data-end=\"3282\">\n<p data-start=\"3235\" data-end=\"3282\">Proven bond stability under ISO 9693 conditions<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"3284\" data-end=\"3287\" \/>\n<h3 data-start=\"3289\" data-end=\"3337\">Dual Workflow: Staining or Layered Porcelain<\/h3>\n<p data-start=\"3339\" data-end=\"3456\">Rather than forcing laboratories into a single technique, Hocera HT supports <strong data-start=\"3416\" data-end=\"3455\">two validated restorative workflows<\/strong>:<\/p>\n<ol data-start=\"3458\" data-end=\"3718\">\n<li data-start=\"3458\" data-end=\"3585\">\n<p data-start=\"3461\" data-end=\"3585\"><strong data-start=\"3461\" data-end=\"3483\">Staining technique<\/strong><br data-start=\"3483\" data-end=\"3486\" \/>Compatible with brush-on systems such as <em data-start=\"3530\" data-end=\"3544\">IPS Ivocolor<\/em> for efficient full-contour restorations.<\/p>\n<\/li>\n<li data-start=\"3587\" data-end=\"3718\">\n<p data-start=\"3590\" data-end=\"3718\"><strong data-start=\"3590\" data-end=\"3621\">Layered porcelain technique<\/strong><br data-start=\"3621\" data-end=\"3624\" \/>Fully compatible with ceramics such as <em data-start=\"3666\" data-end=\"3679\">Creation ZI<\/em>, supported by a <strong data-start=\"3696\" data-end=\"3717\">0.02 mm CTE match<\/strong>.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"3720\" data-end=\"3919\">Because of this thermal compatibility, the zirconia core and veneering ceramic expand uniformly during firing.<br data-start=\"3830\" data-end=\"3833\" \/>This significantly reduces the risk of <strong data-start=\"3872\" data-end=\"3918\">chipping, cracking, or veneer delamination<\/strong>.<\/p>\n<hr data-start=\"3921\" data-end=\"3924\" \/>\n<h3 data-start=\"3926\" data-end=\"3968\">Milling Accuracy &amp; Sintering Stability<\/h3>\n<p data-start=\"3970\" data-end=\"4073\">During CAD\/CAM processing, Hocera HT demonstrates <strong data-start=\"4020\" data-end=\"4052\">predictable milling behavior<\/strong> across open systems.<\/p>\n<ul data-start=\"4075\" data-end=\"4205\">\n<li data-start=\"4075\" data-end=\"4120\">\n<p data-start=\"4077\" data-end=\"4120\">Clean margins with minimal micro-chipping<\/p>\n<\/li>\n<li data-start=\"4121\" data-end=\"4157\">\n<p data-start=\"4123\" data-end=\"4157\">Stable performance in thin areas<\/p>\n<\/li>\n<li data-start=\"4158\" data-end=\"4205\">\n<p data-start=\"4160\" data-end=\"4205\">Reduced tool wear in high-volume production<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4207\" data-end=\"4477\">During sintering, the material maintains a <strong data-start=\"4250\" data-end=\"4282\">shrinkage tolerance of \u00b10.5%<\/strong>, which is <strong data-start=\"4293\" data-end=\"4353\">significantly tighter than the industry average of \u00b11.2%<\/strong>.<br data-start=\"4354\" data-end=\"4357\" \/>Therefore, marginal gaps consistently remain <strong data-start=\"4402\" data-end=\"4412\">\u226430 \u03bcm<\/strong>, improving first-fit accuracy and reducing chairside adjustment.<\/p>\n<hr data-start=\"4479\" data-end=\"4482\" \/>\n<h3 data-start=\"4484\" data-end=\"4516\">CAD\/CAM System Compatibility<\/h3>\n<p data-start=\"4518\" data-end=\"4589\">Hocera HT zirconia blocks are produced in standard open-system formats:<\/p>\n<ul data-start=\"4591\" data-end=\"4640\">\n<li data-start=\"4591\" data-end=\"4610\">\n<p data-start=\"4593\" data-end=\"4610\"><strong data-start=\"4593\" data-end=\"4610\">98 mm \/ 95 mm<\/strong><\/p>\n<\/li>\n<li data-start=\"4611\" data-end=\"4640\">\n<p data-start=\"4613\" data-end=\"4640\"><strong data-start=\"4613\" data-end=\"4640\">92 \u00d7 75 mm (AG systems)<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4642\" data-end=\"4873\">They integrate directly with <strong data-start=\"4671\" data-end=\"4709\">Roland, DWOS, and Exocad workflows<\/strong>, without adapters or special calibration.<br data-start=\"4751\" data-end=\"4754\" \/>As a result, laboratories can standardize one high-strength zirconia solution across multiple machines and indications.<\/p>\n<hr data-start=\"4875\" data-end=\"4878\" \/>\n<h3 data-start=\"4880\" data-end=\"4904\">Clinical Indications<\/h3>\n<p data-start=\"4906\" data-end=\"4935\">Hocera HT is recommended for:<\/p>\n<ul data-start=\"4937\" data-end=\"5125\">\n<li data-start=\"4937\" data-end=\"4981\">\n<p data-start=\"4939\" data-end=\"4981\">Posterior and anterior long-span bridges<\/p>\n<\/li>\n<li data-start=\"4982\" data-end=\"5047\">\n<p data-start=\"4984\" data-end=\"5047\">Full-contour crowns with minimal occlusal reduction (\u22650.5 mm)<\/p>\n<\/li>\n<li data-start=\"5048\" data-end=\"5089\">\n<p data-start=\"5050\" data-end=\"5089\">Implant-supported hybrid restorations<\/p>\n<\/li>\n<li data-start=\"5090\" data-end=\"5125\">\n<p data-start=\"5092\" data-end=\"5125\">Metal-ceramic replacement cases<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"5127\" data-end=\"5264\">By covering multiple indications, the material helps laboratories <strong data-start=\"5193\" data-end=\"5263\">reduce inventory complexity while maintaining clinical reliability<\/strong>.<\/p>\n<p>&nbsp;<\/p>\n<div align=\"start\">\n<div data-relingo-block=\"true\">\n<div style=\"text-align: left;\" data-relingo-block=\"true\" data-spm-anchor-id=\"a2g0o.detail.1000023.i0.6c9eSfv7Sfv7jT\">\n<p>&nbsp;<\/p>\n<\/div>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u200b<strong>\u200bHocera HT Zirconia Block\u200b<\/strong>\u200b:<\/p>\n<p>1350MPa 3Y-TZP zirconia with 38% light absorption for ultimate masking of discolored abutments &amp; metal substrates.<\/p>\n<p>Certified for 14-unit bridges &amp; titanium hybrid abutments. Features \u00b10.5% sintering shrinkage, 0.3mm connector safety, and dual restoration workflows (staining\/layering).<\/p>\n<p>Roland\/DGSHAPE\/Exocad compatible 95mm discs. ISO 6872 &amp; FDA certified.<\/p>\n","protected":false},"featured_media":1735,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[31],"product_cat":[137,136],"product_tag":[227,255,256,275,237,234,259,232,262,253,225,242,265,230,248,264,231,228],"class_list":["post-661","product","type-product","status-publish","has-post-thumbnail","product_brand-hocera","product_cat-white-zirconia-block","product_cat-dental-zirconia-blocks","product_tag-bestseller","product_tag-bridge","product_tag-crown","product_tag-dental-zirconia","product_tag-digital-dentistry","product_tag-dry-milling","product_tag-fast-sintering","product_tag-high-speed-milling","product_tag-high-translucency","product_tag-implant","product_tag-lab-essentials","product_tag-milling-machine","product_tag-monolayer","product_tag-open-system","product_tag-posterior","product_tag-pre-shaded","product_tag-precision-cutting","product_tag-value-series","first","instock","shipping-taxable","product-type-simple"],"acf":[],"_links":{"self":[{"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/product\/661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/comments?post=661"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/media\/1735"}],"wp:attachment":[{"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/media?parent=661"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/product_brand?post=661"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/product_cat?post=661"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/hocera.com\/en\/wp-json\/wp\/v2\/product_tag?post=661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}